Design And Development
DAS CHEMICAL PROCESSED INDUSTRY PVT. LTD. believes in providing complete solution to client needs and over the years we have come across many clients who were new to FRP. DAS CHEMICAL PROCESSED INDUSTRY PVT. LTD. with its expertise in design and development has provided long term solutions with optimized designs and make them familiar with key benefits of using FRP as a replacement of conventional material.
From conceptual model/drawing to final assembly and erection drawings, we provide all sorts of design services through our team of experienced draft-men, designers and structural engineers.
Our simulated results have been calibrated with experimental and theoretical data, this has enabled us to extensively incorporate our simulation skills into designing.
FRP industry is still considered to be one of the emerging industry and as far as design is concerned there are many international codes yet to be developed, as shown below our design is based on various International standards such as CTI, ACMA, ASCE, ISO, EN etc.
- CAD services
- 3D modelling
- 2D drafting
- Fabrication drawings
- Surface models
- Assemblies and animations
- CAE services
- Static Analysis
- Buckling Analysis
- 2D Analysis
- Design optimisation
- Design for prototype development
- Reverse engineering
- Design Failure mode and effects analysis (DFMEA)
- Design for manufacture and assembly (DFMA)
- Material sustainability analysis
Testing
DAS CHEMICAL PROCESSED INDUSTRY PVT. LTD. has in-house testing facility for physico-mechanical testing. From raw material which is purchased from reputed vendors to finished products, we maintain high quality output through continuous batch-wise testing.
We thrive for Continuous improvement of manufacturing processes with emphasis on consistent quality.
At times it is required to step up and take extra measures for client satisfaction for which we develop unique fixtures for various type of testing.
Sr.No. | Test Perameter | UOM | Method Std. | Criteria |
---|---|---|---|---|
1 | Specific Weight | gm/cc | ASTM D792 | 1.72 to 1.94 |
2 | 24 HRS Water Absorption | % | ASTM D570 | Max.0.60 |
3 | Barcol Hardness | BHU | ASTM D2583 | ≥ 45 |
4 | Glass Content | % | ISO 1172 | 60 ± 5 |
5 | 3 point bending/modulus of elastisity (full section) | Gpa | EN ISO 13706 | |
6 | Longitudinal Tensile Strength | Mpa | ASTM D638 | ≥ 206.8 |
7 | Longitudinal Tensile Modulus | Gpa | ASTM D638 | ≥ 17.2 |
8 | Transversal Tensile Strength | Mpa | ASTM D638 | ≥ 48.2 |
9 | Transversal Tensile Modulus | Gpa | ASTM D638 | ≥ 5.5 |
10 | Longitudinal Flexural Strength | Mpa | ASTM D790 | ≥ 206.8 |
11 | Longitudinal Flexural Modulus | Gpa | ASTM D790 | ≥ 11 |
12 | Transversal Flexural Strength | Mpa | ASTM D790 | ≥ 68.9 |
13 | Transversal Flexural Modulus | Gpa | ASTM D790 | ≥ 5.5 |
14 | Longitudinal Compression Strength | Mpa | ASTM D695 | ≥ 206.8 |
15 | Longitudinal Compression Modulus | Gpa | ISO ASTM D695 | ≥ 17.2 |
16 | Transversal Compression Strength | Mpa | ASTM D695 | ≥ 103.4 |
17 | Transversal Compression Modulus | Gpa | ASTM D695 | ≥ 6.9 |
18 | longitudinal Bearing Strength | Mpa | ASTM D953 | ≥ 206.8 |
19 | Transversal Bearing Strength | Mpa | ASTM D953 | ≥ 206.8 |
20 | Short beam sheare (ILSS) | Mpa | ASTM D2344 | 31 |
21 | FR | V0 | ASTM E-84 class A/B/C | V0 |